INTELLIGENT TELEMETRY SOLUTION
Liquid Cooling
Rack Monitoring
System (LCRMS)
Centralized row-level protection and telemetry for high-density environments
Designed to satisfy next-generation computing infrastructure requirements. LCRMS continuously monitors coolant leakage, pressure, temperature, communication health, and operational status at the individual rack level.
Protect critical GPU clusters and mission-critical hardware, prevent failures, and integrate telemetry seamlessly with SCADA, BMS, and DCIM platforms.
Detection (PG/LC-25)
Temp Monitoring
Transmitters
Data Acquisition
Network Redundancy
WHY AUTOMATED MONITORING MATTERS
TRADITIONAL INSPECTIONS
- Trip hazards or hidden leaks
- Manual thermal scans required
- Delayed disaster notifications
- No pressure / flow analytics
- High operational overhead
KLOTA LCRMS SOLUTION
- 24/7 continuous leak detection
- Real-time pressure & temp flow
- Instant alarm notifications
- Redundant power and comms
- Seamless SCADA/BMS integration
SUPPORTING HIGH-DENSITY MISSION CRITICAL ENVIRONMENTS
Hyperscale Data Centers
Reliable rack-level telemetry tracking for large scale cloud-computing systems.
AI GPU Clusters
Precision liquid flow diagnostics for hardware-heavy machine learning infrastructure.
High Performance Computing
Real-time alerts protecting supercomputer liquid cooling setups.
Colocation Facilities
SLA assurance and tenant critical hardware safety systems.
THE ENGINEERING BEHIND KLOTA LCRMS
Dual Power
Redundancy
Features two independent 24VDC power inputs, offering automatic failover for high availability.
Fail-Safe Loop
Communication
RS485 Peer-to-Peer Loop-back design prevents single point of communication failure across rows.
Strategic Multi-Point
Leak Detection
Integrates 5+ PG-25 / LC-25 sensors per rack for immediate pinpointing of coolant leaks.
Local Control &
Protocol Integration
Acquires transmitter telemetry locally and links through Modbus RTU/TCP and BACnet protocols.
Manual Leak Emergency Alert System
Instant human-triggered row level overrides
Manual Leak Alarm Push Buttons are installed at both the start and end of each server rack row. If operators visually identify coolant leakage, hose damage, moisture accumulation, or abnormal coolant pooling, they can trigger an immediate alert.
Manual Alarm Sequence
- Operator pushes the row-end Emergency Button.
- Local Controller instantly triggers visual Strobe Light & Hooter sound alarms.
- Event log registers the specific coordinates on the Main Control Panel.
- Alert broadcasted to SCADA, BMS, and DCIM platforms immediately.
Available Telemetry Points
- ✔ Leak Sensor Status
- ✔ Supply Line Pressure
- ✔ Return Line Pressure
- ✔ Supply Line Temp
- ✔ Return Line Temp
- ✔ Emergency Button Status
- ✔ Loop Connection Health
- ✔ Power Failover Status
- ✔ Hooter & Strobe Output
- ✔ SCADA / Modbus Health
OPERATIONAL VALUE
Prevent Hardware Damage
Identify minor coolant drops before they spill onto active motherboards and GPU cards.
Cooling Efficiency Optimizations
Analyze temperature and pressure differentials to monitor CDU performance efficiency.
Event Response
Local controllers respond in milliseconds, minimizing flow exposure and containing spills.
Unified Control Architecture
Integrate telemetry data points directly with your existing corporate BMS, SCADA, or DCIM.
Ready to Secure Your High-Density Server Racks?
Protect your AI clusters with reliable, centralized Liquid Cooling Rack Monitoring.